Great Plains DICKEY-john IntelliAg Quick Start User Manual

Quick setup guide for intelliag model nta

Advertising
background image

11001-1460C-201107

©2011 DICKEY-john Corporation
Specifi cations subject to change without notice.

Quick Setup Guide for IntelliAg Model NTA

STEP 1: Pre-Programming Preparation:

Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings.
If errors are detected (e.g., failed sensors, incorrect confi guration) an alarm and code will display. Alarms are silenced by pressing the Alarm Cancel button

. Refer to Operator’s

manual for troubleshooting assistance.
The system has three user levels. The system loads in user level 1 (operator level) at every power cycle. Access to user level 2 and 3 screens to setup constants (system confi guration)
requires a password available through an authorized Great Plains dealer.

1.
2.

3.

The Quick Setup Guide assumes the Virtual Terminal, Working Set Master Module, Working Set Member Module, and all sensors
have been connected and properly installed. Quick Setup Guide assumes channel 1 (front bin) to be seed and channel 2 (rear
bin) to be fertilizer. Reference the Operator’s manual for installation instructions.

STEP 3: Auto Confi guration (identifi es sensors connected to each module)
Auto confi g is performed at the factory, but may need to be done in the fi eld as changes
are made to the system or if options are added to the base system.

Verify Auto Confi g results are correct. Check that the correct number of rows are assigned to
the correct module and number of hoppers and pressure sensors are assigned accurately.

To Run Auto Confi g:

Press Next Page

until Module Confi guration button appears.

Press Module Confi guration button

.

Press AUTO CONFIG button

.

Hour glass will indicate system is detecting the presence of seed, pressure, or hopper
sensors connected to each module and automatically assigns to the appropriate module.
When Auto Confi g completes, press the Row Assign button

to display the Row

Assignment screen to verify correct Row # is assigned to the correct module based on serial
number.
Enter # of rows assigned to each module.

1.

1.
2.
3.
4.

5.

6.

STEP 5A: Material Confi guration Setup (Granular Seed Monitor)
16 different materials can be confi gured as seeding and fertilizer controls. Material defaults on
the Control Setup screen are Seed 1-4 (Granular Seed Control) Seed 5-8 (Granular Seed
Monitor) Fert 1-4 (Granular Fertilizer Control) Fert 5-8 (Granular Fertilizer Monitor).
Reference the System Confi guration section in the Operator’s Manual for additional setup
instructions.

Press the Control Setup button

.

At the Control Setup screen, select one of the 16 material buttons to edit (labeled Seed 1-8
and Fert 1-8).
Enter desired values from Table B.
Press the Control Setup button

to return to the Control Setup screen.

Repeat steps 2-4 for additional materials.
Press the Channel Setup button

to enter channel setup constants.

1.
2.

3.
4.
5.
6.

STEP 4: Row Status/Row Width Setup

Press Row I/O button

.

Enter desired values using Table A as reference.
Press Work Screen button

to return to the Main Work screen.

1.
2.
3.

1

# O F

R O W S

MODULE

ADDR.

TYPE

R O W

# ’s

1 - 11

WSMB-18R

11

Seed Sensor Configuration Screen

1 2 - 2 2

S E R I A L
N U M B E R

1

M O D U L E
T Y P E

M O D U L E
A D D R .

WSMB-18R

WSMT-ACCGP

2

10001

10003

WSMB-18R

3

3

WSMB-18R

4

2 3 - 3 3

10004

WSMB-18R

4

10002

Module Configuration Screen

10005
10006

WSMB-18R

WSMB-18R

6

5

5

WSMB-18R

WSMB-18R

WSMB-18R

11

11
11

3 4 - 4 4
4 5 - 5 5

6

2

Above screens depict setup for 55 row
For 30 ft. 36 row (# of rows = 9) (4 towers)
For 35 ft. 40 row (# of rows = 8) (5 towers)
For 30 ft. 48 row (# of rows = 12) (4 towers)

11

TABLE B:

Gran Seed Mon

Material Setup

Default Value/

Value to Enter

Instructions/Defi nitions

Matrl Label

Seed 5

Material Name can be customized to accurately defi ne the
material’s type. Creating a name allows for quick identifi cation at
the Material Summary screen.

Type

Gran Seed Monitor

Type of application control channel used for a specifi c material.
The Material Type must correctly match the Control Type to select
Material from the Material Summary screen and operate properly.

Display Units

Lbs/Ac with

revs/acre

Displays primary and secondary readout units.

Target Rate

60

Desired rate of application in lbs/Ac.

Density

60.0

Establishes the density of material. Density units can be entered in
lbs/bu or lbs/ft

3

.

# Outlets per Meter Box

5 (35 ft)

Establishes the number of towers for that channel.

# Outlets per Meter Box

4 (30 ft)

Calibration Constant

77600

Number of pulses to drop 1 cubic foot of material.

Variable Cal Constant

Disabled

Adjusts the accuracy of the seed mount dispensed based on the
seed type. A selection of 25 pre-defi ned seed types are available.

Seeds per Pound

3000

Set to number of seeds per pound.

Low Shaft RPM

1

Set to desired min seed meter RPM.

High Shaft RPM

50

Set to desired max seed meter RPM.

High Pop Alarm

20

This is the percentage above the target population of the seeder
channel if rows are assigned to the seeder channel. If rows are not
assigned to a seeder, this is the percentage above average seeder
population for all unassigned rows.

Low Pop Alarm

20

This is the percentage below the target population of the seeder
channel if rows are assigned to the seeder channel. If rows are not
assigned to a seeder channel, this is the percentage below average
seeder population for all unassigned rows.

On/Off Pattern

Every Row On

On/Off Pattern indicates specifi c row patterns to be on or off. Select
pre-defi ned seeder All Row On pattern. For other seed patterns or
individual row settings, reference Operator’s manual.

Row Fail Rate

2/1

Sets the threshold for row failure alarms. Entered in seeds per
second. 2/1 is a row failure threshold of 2 seeds in 1 second.

TABLE A: Row

Status/Row

Width Setup

Default Value/

Value to Enter Instructions/Defi nitions

Row Width
(36 row) 30 ft.

10

Enter row width distance in inches to calculate seed rate data (360).

Row Width
(40 row) 35 ft.

10

Enter row width distance in inches to calculate seed rate data (400).

Row Width
(48 row) 30 ft.

7.5

Enter row width distance in inches to calculate seed rate data (364).

Row Width
(55 row) 35 ft.

7.5

Enter row width distance in inches to calculate seed rate data
(416.5).

Auto Update Width

Disabled

When enabled, implement width will automatically calculate. If
disabled, manually enter implement width.

Implement Width
(35 ft. 55 row) 7.5”

416.5

Manually enter implement width in inches.

Implement Width
(35 ft. 40 row) 10”

400

Implement Width
(30 ft. 48 row) 7.5”

364

Implement Width
(30 ft. 36 row) 10”

360

On/Off Pattern

Every row on

On/Off Pattern indicates specifi c row patterns to be on or off. Select
pre-defi ned seeder All Row On pattern. For other seed patterns or
individual row settings, reference Operator’s Manual.

Pop/Block Pattern

Every row blockage

Determines which sensors are used to calculate population and
those used only for blockage detection. Select Every Row Blockage.
For other patterns, reference Operator’s Manual.

Proceed to Step 5C if a variable rate kit is installed.

STEP 2: Change User Level to Dealer Level
To change the user level, a 6-digit password is required. Password includes the fi ve-digit

serial number found on the label of the working set master or Information screen.

On the IntelliAg Main Work screen, press the Diagnostics button

.

At the Diagnostics screen, press the Information button
At the Information screen, record serial number of WSMT.
Press the Password button

.

On the Password screen, enter the 6-digit password as follows: enter the fi rst digit as 2 for
User Level 2. For the next fi ve digits, enter the Working Set Master serial number taken from
the WSMT or Information screen.
Press the OK button . “Dealer screens on” appears at the bottom of screen confi rming
the password and dealer screens are activated.
Press the Work Screen button to return to the Main Work screen.

1.
2.
3.
4.
5.

6.

7.

Advertising