STEP 6A: Channel Setup (Granular Seed Monitor)

Channel 1 is generally used for granular seed monitor setup.

At the Channel Setup screen, verify that channel 1 is set to
granular seed monitor.
Enter desired values using Table D as reference.
To set up additional control channels (granular fert monitor,
granular fert control, granular seed control, RPM Control),
press the Next Channel button

.

When channel setup is complete, press the Work Screen but-
ton

to return to the Main Work screen.

Once a control channel has been established as granular seed
monitor, any new materials established as granular seed moni-
tor on the Material Setup screen will automatically be added
as optional materials for granular seed monitor channels on
the Control Setup screen.

1.

2.
3.

4.

STEP 5B: Material Confi guration Setup
(Granular Fertilizer Monitor)

16 different materials can be confi gured as seeding and fertilizer
controls. Material defaults on the Control Setup screen are Seed
1-4 (Granular Seed Control) Seed 5-8 (Granular Seed Monitor)
Fert 1-4 (Granular Fertilizer Control) Fert 5-8 (Granular Fertilizer
Monitor). Reference the System Confi guration section in the
Operator’s manual for additional setup instructions.

Press the Control Setup button

.

At the Control Setup screen, select one of the 16 material
buttons to edit (labeled Seed 1-8 and Fert 1-8).
Enter desired values from Table C.
Press the Control Setup button

to return to the Control

Setup screen.
Repeat steps 2-4 for additional materials.
Press the Channel Setup button

to enter channel

setup constants.

1.
2.

3.
4.

5.
6.

2

TABLE E

Channel Setup

Gran Seed Mon

Default Value/

Value to Enter

Instructions/Defi nitions

Type

Gran Seed

Monitor

Set desired Channel Type as Gran Seed Monitor.

Material Name

Seed 5

Displays only materials that have been confi gured for the channel type.

Input Filter

50

Feedback frequency fi lter for the Control Channel. DO NOT CHANGE.

Sensor Constant

360

Sensor Constant establishes the number of pulses for one revolution of the feedback

sensor. If a DICKEY-john application rate sensor is used, set value to 360.0.

Gear Ratio

1.0

Specifys the actual ratio from the feedback sensor to the seed meter shaft RPM. # of

revolutions feedback sensor turns in relation to one revolution the seed meter turns.

# of Seed Rows

(determined by row

spacing)

40 or 55 row

Entry of a specifi c number of seed rows to the Control Channel. Row assignment is

given a priority based on the Channel and will be assigned sequentially thereafter.

Channel 1 is always assigned to the fi rst set of rows, Channel 2 next set of rows, and

so on.

36 or 48 row

Channel Width (35 ft.

55 row) 7.5”

416.5

Manual entry of channel width for rows assigned to a specifi c channel. Width calcula-

tion determined by # of seeder rows assigned to the channel multipled by the row

spacing.

Channel Width (30 ft. 48 row = 364)

Channel Width (30 ft. 36 row = 360)

Channel Width (35 ft.

40 row) 10”

400

TABLE C:

Material Setup

Gran Fert Monitor

Default Value/

Value to Enter

Instructions/Defi nitions

Matrl Label

Fert 5

Material Name can be customized to accurately defi ne the material’s type. Creating a

name allows for quick identifi cation at the Material Summary screen.

Type

Gran Fert Monitor

Desired type of application control channel being used for a specifi c material. The

Material Type must correctly match the Control Type to be able to select material from

the Material Summary screen and operate properly.

Units

Lbs/Ac with

revs/acre

Displays primary and secondary readout units.

Target Rate

50

Desired rate of application in lbs/Ac.

Density

60

Establishes the density of material in lbs/ft

3

.

# Outlets per Meter Box

5 (35 ft)

Establishes the number of towers for that channel.

# Outlets per Meter Box

4 (30 ft)

Calibration Constant

82500

Number of pulses to drop 1 cubic foot of material.

Variable Cal Constant

Disabled

Adjusts the accuracy of the seed amount dispensed based on the seed type. A selec-

tion of 25 pre-defi ned seed types are available.

Low Shaft RPM

1

Set to desired min fert meter RPM.

High Shaft RPM

50

Set to desired max fert meter RPM.

On/Off Pattern

Every Row On

On/Off Pattern indicates specifi c row patterns to be on or off. Select pre-defi ned seed

All Row On pattern. For other seed patterns or individual row settings, reference

Operator’s manual.

Row Fail Rate

2/1 (2 seeds

every 1 second)

Set to desired number of seeds per second to trigger seed sensor failure alarm.

Step 5C only applies to those applications with a
variable rate kit option installed. Proceed to Step 6A if
variable rate is not applicable.

STEP 5C: Material Confi guration Setup
(Granular Seed or Fert Control)

16 different materials can be confi gured as seeding and fertilizer
controls. Material defaults on the Control Setup screen are Seed 1-
4 (Granular Seed Control) Seed 5-8 (Granular Seed Monitor) Fert
1-4 (Granular Fertilizer Control) Fert 5-8 (Granular Fertilizer Moni-
tor). Reference the System Confi guration section in the Operator’s
manual for additional setup instructions.

Press the Control Setup button

.

At the Control Setup screen, select one of the 16 material
buttons to edit (labeled Seed 1-8 and Fert 1-8).
Enter desired values from Table D.
Press the Control Setup button

to return to the Control

Setup screen.
Repeat steps 2-4 for additional materials.
Press the Channel Setup button

to enter channel setup

constants.

1.
2.

3.
4.

5.
6.

TABLE D:

Material Setup

Gran Seed/Fert

Default Value/

Value to Enter

Instructions/Defi nitions

Matrl Label

Seed 1/Fert 1

Material Name can be customized to accurately defi ne the material’s type. Creating a

name allows for quick identifi cation at the Material Summary screen.

Type

Gran Seed/Gran

Fert Ctrl

Desired type of application control channel being used for a specifi c material. The

Material Type must correctly match the Control Type to be able to select material from

the Control Setup screen and operate properly.

Units

Lbs/Ac

Displays primary and secondary readout units in Lbs/ac or Kg/ha.

Target Rate

50 lbs/Ac

Desired rate of application in lbs/Ac.

Inc/Dec %

1%

Percent of change of entered target rate each time the Inc/Dec button is pressed.

Max Rate

78 lbs

Max application rate in lbs per acre the control will allow.

Min Rate

48 lbs

Min application rate in lbs per acre the control will allow.

Density

60 lbs/ft

3

/bu

Establishes the density of material in lbs/ft

3

/bu.

# Outlets per Meter Box

5 (35 ft)

Establishes the number of towers for that channel.

# Outlets per Meter Box

4 (30 ft)

Calibration Constant

82500 Pul/ft

3

Number of pulses to drop 1 cubic foot/liter of material.

Variable Cal Constant

Disabled

Adjusts the accuracy of the seed amount dispensed based on the seed type. A selec-

tion of 25 pre-defi ned seed types are available.

Low Shaft RPM

1

Set to desired min meter RPM.

High Shaft RPM

50

Set to desired max meter RPM.

Prod Level Alarm

0

Sets the weight to trigger alarm indicating low fertilizer levels in lbs.

Row Fail Rate

2/1 (2 seeds

every 1 second)

Set to desired number of seeds per second to trigger seed sensor failure alarm.

Proceed to Step 6C if a variable rate kit is installed.