Quick Setup Guide for IntelliAg Model NTA

STEP 6B: Channel Setup (Granular Fertilizer Monitor)

Channel 2 is generally used for granular fertilizer monitor setup.

At the Channel Setup screen, press the Next Channel button

to setup additional control channels.

Set channel 2 as granular fertilizer monitor.

Enter desired values using Table F as reference.

Continue to set up control channels 3 and 4, if required.

Press the Work Screen Button

when channel confi gu-

rations are complete to return to the Main Work screen.

Once a Control Channel has been established as Granular Fertil-
izer Monitor, any new materials established as granular fertilizer
monitor on the Material Setup screen will automatically be added
as optional materials for granular fertilizer monitor channels on
the Control Setup screen.

1.

2.

3.

4.

5.

TABLE F:

Channel Setup

Gran Fert Mon

Default Value/

Value to Enter

Instructions/Defi nitions

Type

Gran Fert Monitor

Set desired Channel Type as Gran Fert Monitor.

Material Name

Fert 5

Displays only materials that have been confi gured for the channel type.

Input Filter

50

Feedback frequency fi lter for the control channel. DO NOT CHANGE.

Sensor Constant

360

Sensor Constant establishes the number of pulses for one revolution of the feedback

sensor. If a DICKEY-john application rate sensor is used, the value should be set to

360.0.

Gear Ratio

1.0

Specifys the actual ratio from the feedback sensor to the seed meter shaft RPM.

Number of revolutions the feedback sensor turns in relation to one revolution the seed

meter turns.

Channel Width

(35 ft. 55 row) 7.5”

416.5

Manual entry of the channel width for rows assigned to a specifi c channel. Width

calculation can be determined by # of seeder rows assigned to the channel multipled

by the row spacing.

Channel Width

(35 ft. 40 row) 10”

400

Channel Width

(30 ft. 48 row) 7.5”

364

Channel Width

(30 ft. 36 row) 10”

360

Step 6C only applies to those applications with a
variable rate kit option installed. Proceed to step 7 if
variable rate is not applicable.

STEP 6C: Channel Setup (Granular Seed & Fertilizer
Control)

Press the Channel Setup button

.

Select an available channel and set to either granular seed

control or granular fertilizer control.

Enter desired values using Table G as reference.

To set up additional control channels, press the Next Channel

button

.

Press the Work Screen button

when channel confi gu-

rations are complete to return to the main menu.

1.

2.

3.

4.

5.

TABLE G:

Channel Setup

Gran Seed &

Fert Setup

Default Value/

Value to Enter

Instructions/Defi nitions

Type

Gran Seed

Control/Gran Fert

Control

Set desired Channel Type as either Gran Seed Control or Gran Fertilizer Control.

Material Name

Seed 1/Fert 1

Displays only materials that have been confi gured for the channel type.

Control Mode

Auto

Calculates application rates based on ground speed and channel width under normal

operating conditions.

Drive Type

Zero Max

A Zero Max gear box controlled by a linear actuator for those applications with an

installed variable rate kit option.

Drive Frequency

40

The Hz frequency for the linear actuator specifi ed by the valve manufacturer.

Input Filter

50

Feedback frequency fi lter for the control channel. DO NOT CHANGE.

Sensor Constant

360

Sensor constant establishes the number of pulses for one revolution of the feedback

sensor. If a DICKEY-john application rate sensor is used, the value should be set to

360.0.

Gear Ratio

1.0

Specifys the actual ratio from the feedback sensor to the seed meter shaft RPM.

Number of revolutions the feedback sensor turns in relation to one revolution the seed

meter turns.

Grd Spd/Trans In

Ratio

45

Ratio between distance traveled to one revolution of the input to the Zero Max transmis-

sion. Ratio determines the input sprocket speed from the known ground speed.

Meter Gear Range

High/Low

Determined by the position of the interchangeable gears. High range used for larger

seeds and higher seeding rates. Low range used for smaller seeds and lower seeding

rates. Refer to Great Plain’s operator’s manual for recommended high/low setting.

# of Seed Rows

36 row

Entry of a specifi c number of seed rows to the control channel. Row assignment is given

a priority based on the channel and will be assigned sequentially thereafter. Channel 1

is always assigned to the fi rst set of rows. Channel 2 next set of rows, and so on.

40 row

48 row

55 row

Channel Width

(35 ft. 55 row) 7.5”

416.5

Manual entry of the implement width for rows assigned to a specifi c channel. Width

calculation can be determined by # of seeder rows assigned to the channel multipled by

the row spacing.

Channel Width

(35 ft. 40 row) 10”

400

Channel Width

(30 ft. 48 row) 7.5”

364

Channel Width

(30 ft. 36 row) 10”

360

Flush Enable

Disabled

Not applicable to ground drive systems.

Precharge Time

+ 0.0

Not applicable to ground drive systems.

Delay Time

- 0.0

Not applicable to ground drive systems.

3