Hydraulic down pressure all openers – Great Plains 3S-4000F Operator Manual User Manual

Page 58

Advertising
background image

54

3S-4000

Table of Contents

Index

Great Plains Manufacturing, Inc.

195-394M

Table of Contents

Index

2014-06-10

Table at right shows the approximate force at openers for
a given pressure at the pressure control valve.

Note: To account for additional compaction from drill and

tractor tires, set pressure on center openers slightly
higher than wing openers.

Hydraulic Down Pressure All Openers

To run the drill with constant opener down pressure
requires an Active Hydraulic System. An Active Hydraulic
System requires a tractor with closed-center hydraulics
or pressure/flow compensated hydraulics powered by a
variable displacement hydraulic pump. (If you are not
familiar with your tractor’s hydraulics, consult your tractor
dealer.)

Tractors with load-sensing hydraulics must use the bypass
valve to operate the 3S-4000. Failure to use the bypass valve
can cause major tractor damage. Before adjusting opener
down pressure, set bypass valve as explained under “Setting
the Bypass Valve
” on page 28.

Note: To run the drill on tractors with open-center

hydraulics or on tractors with fixed displacement
hydraulic pumps you must install a Great Plains kit,
part number 194-143A. Contact your Great Plains
dealer for ordering information. See “Non-Active
Hydraulic System
” on page 32.

To set down pressure:

1.

Lower openers to the ground. Lock hydraulic lever
forward for constant hydraulic flow.

You must lock hydraulic lever forward. See “Opener
Operation
” on page 30, for instructions.

Refer to Figure 57
2.

Turn knob on pressure-control valve while watching
pressure gauge, turn knob until gauge shows
desired pressure. Turn clockwise to increase
pressure. Turn counterclockwise to decrease
pressure.

There is one pressure-control valve for openers on
the center section and one for openers on the wing
sections of the drill.

As a general starting point, set hydraulic down
pressure to 1000 psi. For most field conditions,
adjust down pressure between 200 and 1600 psi.

Hydraulic Down-Force

Gauge

Setting

Pounds of Force at Opener Disks

6 inch

rows

7 1/2 in

rows

10 inch

rows

200 PSI

83

86

92

300 PSI

90

95

102

400 PSI

97

103

113

500 PSI

103

111

124

600 PSI

110

119

135

700 PSI

117

128

146

800 PSI

123

136

157

900 PSI

130

144

167

1000 PSI

137

152

178

1100 PSI

143

161

189

1200 PSI

150

169

200

1300 PSI

157

177

211

1400 PSI

163

185

222

1500 PSI

170

194

233

1600 PSI

176

202

244

1700 PSI

183

210

254

1800 PSI

190

218

264

Figure 57

Pressure Control Valves

15557

Advertising