Ultrasonic tab

Ultrasonic parameters – Peak Combo 1 (or 2)

Enable Select this checkbox to ensure the monitor begins

taking upward ultrasonic depth readings at the designated
interval upon activation.

Flow Type Select the option that most accurately reflects

the kind of flow conditions that typically occur at the
monitoring point.

Typical Flow exhibits a typical diurnal pattern.

Wet/Stagnant Flow remains in the pipe, but moves only
during wet weather events.

Usually Dry Pipe typically remains dry, except under wet
weather conditions.

Electronic Offset Enter the difference that exists between

the depth sensor readings and the manually measured depth.