Digital card device, Float device – ADS Environmental Services Profile Software 950015B6 User Manual

Page 74

Advertising
background image

2-34

Profile Software User's Guide

CONFIDENTIAL – Covered by ADS Software License Agreement

1998 – 2012 ADS LLC. All Rights Reserved.

Username Enter the username through which the monitor

can access the FTP site.

Password Enter the password through which the monitor

can access the FTP site.

Digital Card Device

Select the Digital Card 1 or Digital Card 2 device for pump
station applications. If channels 1 through 8 are assigned to the
pumps, select the Digital Card 1 device. If channels 9 through 16
are assigned to the pumps, select the Digital Card 2 device.

Digital Card devices do not require editing.

Float Device

Edit the float device(s) for each float switch connected to the
FlowAlert monitor in the following way. Although configuration of
both floats (when applicable) occurs on the same dialog, each float
represents an independent device.

Edit Float Switch Parameters

Enable Select the checkbox(es) in the Float 1 and/or

Float 2 sections to activate up to two float devices for the
FlowAlert monitor.

Alarm Select the type of alarm you want the Float device

to trigger when the flow reaches the corresponding depth
level. Choose from High, High High, or Low Depth
from this drop-down list. If the High or High High alarm
is configured for the pressure sensor, it will be unavailable
for the Float device.