the High High Depth Alarm Threshold and Return to
Normal
fields.

Threshold Enter the flow depth above which you want
the monitor to contact the IntelliServe system to initiate a
High High Depth alarm. This value must be zero when
not in use or at least 2 inches greater than the value entered
for the High Threshold when it is in use.

Note: To prevent potential false alarms, input a value
greater than 1 into the Readings to Average field of the
Unidepth Averaging section.

Return to Normal Enter the flow depth below which
you want the monitor to send a message to the ADS
IntelliServe system indicating the high, high depth
conditions no longer exist at the monitor.

Low Depth Alarm Set up the following parameters when

you want the FlowShark monitor to send a Low Depth Alarm
message to an ADS IntelliServe system when specific low
flow depth conditions occur at the monitor.

Enable Select this checkbox to enable the Low Depth
Alarm
function using the conditions specified in the Low
Depth Alarm
Threshold and Return to Normal fields.

Threshold Enter the flow depth below which you want
the monitor to contact the ADS IntelliServe system to
initiate a Low Depth alarm. This depth should be lower
than the lowest depth that commonly occurs at the
location.

Note: To prevent potential false alarms, input a value
greater than 1 into the Readings to Average field of the
Unidepth Averaging section.

Return to Normal Enter the flow depth at which you
want the monitor to send a message to the ADS
IntelliServe system indicating the low depth conditions no
longer exist at the monitor.