• +/- Enter the accuracy (plus/minus) for the measured depth.

This is the level of accuracy of the depth reading based on the
field crew's ability to obtain accurate measurements. For
example, a factor that could influence accuracy may be a
choppy flow surface.

• PeakVel Enter the manually obtained peak velocity of the

flow.

• +/- Enter the plus/minus accuracy of the peak velocity.

• AvgVel This field displays the results of the PeakVel

multiplied by the Average-to-Peak ratio (from the Average-
to-Peak
table created in the Installation Generator or using
the .90 default ratio).

• Quantity Use this column to enter the field-measured quantity

for a quantity confirmation.

• +/- Enter the plus/minus accuracy of the quantity confirmation.

• Calc/Q This field displays the calculated quantity based on

the confirmation information.

• Silt Enter the silt depth, if any, at the monitoring point as

measured during the field confirmation. The default value is 0
inches. This field can be widened to accommodate larger
numbers, if necessary.

• HC This field displays the calculated hydraulic coefficient

derived from the field confirmation.

• Roughness This field displays the calculated roughness

derived from the field confirmation or a manually set
roughness.

• Slope This field displays the calculated slope derived from

field confirmations or a manually set slope.

• Crew Enter the name or identification of the field crew who

performed the confirmation.

• Comments Enter any information relevant to the field

confirmation, such as unusual or unique conditions at the