User manual Scatec-10 / -15

27 / 44

Baumer Electric AG

Version 2011-03

www.baumer.com

Frauenfeld, Switzerland


A4:

SW-Revision


aaaaaaa

Version of the Scatec operation software

version consists of 6 numbers plus one
letter (example: 060421a)


A5:

Type



FLDM170

Scatec type


A6:

Remote Param


abcd CAN

CAN Interface
a CAN mode

0 = value of CAN Object 2000 is 3

1 = value of CAN Object 2000 is not 3

b Compensation of synchronization point

(CAN-object2300, subindex 02, bit 0)

0 = off

1 = on

c Inserting missing counts

(CAN-object2300, subindex 02, bit 1)

0 = off

1 = on

d Automatic sensitivity adjustment

(CAN-object2300, subindex 02, bit 2)

0 = off

1 = on



10.3.2 Menu B:

Locks

[Locks]


To protect the sensor against accidental or unauthorized manipulation of the parameter settings, the input
can be blocked in this menu. With a locked sensor, navigation is still possible.

There are two security levels. By default, the sensor is on the lower security level where unlocking is done by
setting parameter [B1] to off.

The sensor will be locked again if no key is pressed for 30 minutes

On a higher security level, the sensor can be protected against unauthorized tampering by requiring the user
to enter an ID code before the sensor will be unlocked. This higher security level can be activated by setting
parameter [F5], Lock-ID-code, to on.

The ID-code (which is asked for) is 55 and cannot be changed.

Submenu

Values

Comments


B1:

Input Lock


0 = off
1 = on


sensor unlocked
sensor locked


B2:

Unlock Code


xxx


ID-code is 55 and can not be changed.
(the ID-code-locking is activated in submenu
F5).