Sensitivity

Scatec-10:

edge thickness 0.1 mm and greater

highest sensitivity 68 … 72 mm beneath sensor

product speed for edge thickness 0.10 mm … 0.2 mm slower than 1 m/s

Scatec-15:

edge thickness 0.15 mm and greater

highest sensitivity 97 … 103 mm beneath sensor

product speed for edge thickness 0.15 mm … 0.2 mm slower than 1 m/s


The sensitivity is dependant on distance and product speed.

Typical sensitivity characteristic see diagram below.







11.9 Default values


Operational parameters

see section 9.1 Flow chart for setting the operational parameters


CAN-interface parameters

refer to the Scatec-15 CAN-Manual

0.0

0.2

0.4

0.6

0.8

1.0

1.2

20

30

40

50

60

70

80

90

100

110

120

130

Working distance d [mm]

E

d

g

e

t

h

ic

k

n

e

s

s

k

[

m

m

]

Scatec-10 FLDM 170x1011/S42 Sensitivity

highest

m edium

low

How to read the graphics: An edge with thickness k at distance d will typically be detected if the
corresponding point in the graphics is above the curve representing the configured sensitivity level.
Test objects: cleanly trimmed flat matt paper sheet tightly lying on a flat matt white sheet of paper.

typical sensitivity characteristics for object speed < 2m/s