11.4 Output connection
11.4.1 Push-pull output (FLDM 170G...)
11.4.2 Opto-isolated output (FLDM 170C...)
Polyfuse
Pin 3
Sensor
Load
Load
Output voltage at V
S
= 24V
Output connected as
Current source
Current sink
V
Out
GND
GND
V
Out
max. 1 V
min. 19 V
min. 23 V
max. 4.5 V
24 V
24 V
Output
+ V
S
Pin 1
GND
+V
s
Operating voltage (+10VDC ... +30VDC)
V
out
Output signal
I
Load
maximum 100 mA
Main connector
Pin 6
V
+V
S
V
+V
S
load
load
Output connected as
Current source
Current sink
V
2
GND
GND
V
1
typ. 0V
min. Vout - 4V
typ. Vout
max. 4V
Vout
Polyfuse
Pin 6
Pin 2
Pin 1
Pin 3
V
+V
out
+V
out
V
+V
out
-V
out
Sensor
+V
S
GND
+V
S
Operating voltage (+10VDC ... +30VDC)
+V
out
Output signal +
-V
out
Output signal -
GND
0 V
R
Load
maximum 50 kOhm
I
Load
maximum 100 mA
Switchable voltage (+Vout minus -Vout) maximum 40 V
Pin 1
Pin 2
Main connector