11.7 Optical data

Laser

Wavelength

650 nm - 680 nm (visible red)

Pulse frequency

50 kHz

Duty cycle

50%

Average power

< 1.0 mW

Laser class

2 (to IEC 60825-1 / 2007)

Beam dimensions

at emission point

about 2.5 x 4.0 mm

Scatec-10:

70 mm beneath sensor

Line focus, 6 mm long

Scatec-15:

100 mm beneath sensor

Line focus, 8 mm long

Focus position

Scatec-10:

70 mm beneath sensor

Scatec-15:

100 mm beneath sensor

Optical receiver

equipped with near infrared suppression and daylight suppression filter

11.8 Application data

Measuring range

Scatec-10:

0 to 90 mm beneath sensor

Scatec-15:

0 to 120 mm beneath sensor

Mounting height

Scatec-10:

70 mm

Scatec-15:

100 mm

Object speed

2 m/s maximum (5 m/s maximum for thicker edges)

Minimum object spacing

10 mm @ v = 1 m/s and output pulse length 10 ms, or proportional to the
speed and output pulse length

Counting rate

1.5 million maximum copies/h (@ 2 ms output pulse length and 0 ms dead
time)

Product orientation

Folded or cut edge facing laser beam

Output pulse length

0.2 … 100 ms adjustable