10.3.3 Menu C:

Parameters

[Parametrs]

Operational parameters are set in menu C. A detailed description of these parameters is given in section 9
Setting the operational parameters
.

Submenus not applicable in the present setting will be skipped in the display!

With the sensor locked, no parameters can be changed while navigation is still possible. The sensor can
be unlocked in menu B. When trying to change a parameter of a locked Scatec, the message “input
locked” will show up as reminder.

The sensor will be locked again if no key is pressed for 30 minutes

Submenu

values

Comments

C0:

Pulse Length

xx.x ms

Output pulse length in ms

value of output pulse length in milliseconds

C1:

RunDirection

0 = lead

1 = trail

Running direction of the copies

leading

trailing

C2:

Fp-Suppress

0 = off

1 = on

False pulse suppression

no false pulse suppression mode will be activated

a false pulse suppression mode as defined in [C3]
will be activated

C3:

Suppr.Mode

00 = dyn

01 = sync

02 = fixed
03 = reflx

False pulse suppression mode

dynamic

synchronous

fixed

retro-reflective foil only

C4:

Dead Time %

xxx

Dead time in percentage

value of dynamic dead time in percentage of the mean
interval between copies

C5:

Encodr Resol

x.xx mm

Encoder resolution in mm/pulse

value of encoder resolution in millimeters per
encoder pulse

C6:

Dead Path mm

xxx mm

Dead path in mm

value of synchronized dead path mm

C7:

Encoder A/B

0 = off

1 = on

Encoder A/B

only A-channel of encoder is used

A- and B-channels of encoder are used

C8:

Dead Time ms

xxx ms

Dead time in ms

value of fixed dead time in milliseconds

C9:

Pulse Delay

0 = off

1 = on

Output pulse delay

output pulse issued immediately after end of the edge

output pulse issued with delay relative to end of the
edge