10.3.3 Menu C:

Parameters

[Parametrs]

Operational parameters are set in menu C. A detailed description of these parameters is given in section 9
Setting the operational parameters
.

•

Submenus not applicable in the present setting will be skipped in the display!

•

With the sensor locked, no parameters can be changed while navigation is still possible. The sensor can
be unlocked in menu B. When trying to change a parameter of a locked Scatec, the message “input
locked” will show up as reminder.

•

The sensor will be locked again if no key is pressed for 30 minutes

Submenu

values

Comments

C0:

Pulse Length

xx.x ms

Output pulse length in ms

value of output pulse length in milliseconds

C1:

RunDirection

0 = lead

1 = trail

Running direction of the copies

leading

trailing

C2:

Fp-Suppress

0 = off

1 = on

False pulse suppression

no false pulse suppression mode will be activated

a false pulse suppression mode as defined in [C3]
will be activated

C3:

Suppr.Mode

00 = dyn

01 = sync

02 = fixed
03 = reflx

False pulse suppression mode

dynamic

synchronous

fixed

retro-reflective foil only

C4:

Dead Time %

xxx

Dead time in percentage

value of dynamic dead time in percentage of the mean
interval between copies

C5:

Encodr Resol

x.xx mm

Encoder resolution in mm/pulse

value of encoder resolution in millimeters per
encoder pulse

C6:

Dead Path mm

xxx mm

Dead path in mm

value of synchronized dead path mm

C7:

Encoder A/B

0 = off

1 = on

Encoder A/B

only A-channel of encoder is used

A- and B-channels of encoder are used

C8:

Dead Time ms

xxx ms

Dead time in ms

value of fixed dead time in milliseconds

C9:

Pulse Delay

0 = off

1 = on

Output pulse delay

output pulse issued immediately after end of the edge

output pulse issued with delay relative to end of the
edge