Installation requirements, Important, Warning – FRIGIDAIRE FFRG1001PW User Manual

Page 10: Clearance requirements, Dryer dimensions

Advertising
background image

10

INSTALLATION REQUIREMENTS

NOTE

To achieve an installation with 0” (0 cm) clearance

for the back of the dryer (for other than straight back

venting), a quick-turn 90° dryer vent elbow must be

installed as described previously in this manual.

* Dryer must be vented straight back to achieve

0” (0 cm) rear installation.

MINIMUM INSTALLATION CLEARANCES - Inches (cm)

SIDES

REAR

TOP

FRONT

Alcove

0” (0 cm)

0” (0 cm)* 23” (58.5 cm)

n/a

Closet

0” (0 cm)

0” (0 cm)* 23” (58.5 cm) 1” (2.5 cm)

1”

(2.5 cm)

0”

(0 cm)

23”

(58.5 cm)

Clearance requirements

IMPORTANT

DO NOT INSTALL YOUR DRYER:
1 In an area exposed to dripping water or outside

weather conditions.

2 In an area where it will come in contact with

curtains, drapes, or anything that will obstruct

the fl ow of combustion and ventilation air.

3 On carpet. Floor MUST be solid with a maximum

slope of 1 inch (2.54 cm).

0”

(0 cm)

0”

(0 cm)

WARNING

EXPLOSION HAZARD

Do not install the dryer where gasoline or other

fl ammables are kept or stored. If the dryer is installed

in a garage, it must be a minimum of 18 inches (45.7

cm) above the fl oor. Failure to do so can result in

death, explosion, fi re or burns.

13.50”

(34.5 cm)

to center of rear vent

centerline height

for rear vent

27” (68.5 cm)

29” (73.5 cm)

to front of closed door

50” (127 cm)

to clear open door

fl oor line

1.6”

(4 cm)

3.75”

(9.5 cm)

3.7”

(9.5 cm)

42.5”

(108 cm)

38.5”

(98 cm)

gas supply

pipe on rear

of gas unit

electrical

supply on

rear of unit

1

Dryer Dimensions

1

Power supply cord length on gas unit approximately 60 inches (152.5 cm).