Installation requirements – FRIGIDAIRE FFRG1001PW User Manual

Page 9

Advertising
background image

9

INSTALLATION REQUIREMENTS

Manufactured or mobile home installation

1 Installation MUST conform to current Manufactured

Home Construction & Safety Standard, Title 24

CFR, Part 32-80 (formerly the Federal Standard

for Mobile Home Construction and Safety, Title 24,

HUD Part 280) or Standard CAN/CSAZ240 MH.

2 Dryer MUST be exhausted outside (outdoors, not

beneath the mobile home) using metal ducting

that will not support combustion. Metal ducting

must be 4 inches (10.16 cm) in diameter with no

obstructions. Rigid metal duct is preferred.

3 If dryer is exhausted through the fl oor and area

beneath the mobile home is enclosed, the exhaust

system MUST terminate outside the enclosure with

the termination securely fastened to the mobile

home structure.

4 Refer to previous sections in this guide for other

important exhaust venting system requirements.

5 When installing a gas dryer into a mobile home, a

provision must be made for outside make up air.

This provision is to be not less than twice the area

of the dryer exhaust outlet.

6 Installer MUST anchor this dryer to the fl oor

with approved Mobile Home Installation Kit - P/N

137067200.

60 sq. in.

(387.1cm²)

3”

(7.6cm)

60 sq. in.

(387.1cm²)

3”

(7.6cm)

closet door

Installation in a Recess or Closet

1 A dryer installed in a bedroom, bathroom, recess or

closet, MUST be exhausted outdoors.

2 No other fuel burning appliance shall be installed in

the same closet as the gas dryer.

3 Your dryer needs the space around it for proper

ventilation.

DO NOT install your dryer in a closet with a solid door.

4 Closet door ventilation required: A minimum

of 120 square inches (774.2 cm²) of opening,

equally divided at the top and bottom of the

door, is required. Openings should be located 3

inches (7.6 cm) from bottom and top of door.

Openings are required to be unobstructed when a

door is installed. A louvered door with equivalent

air openings for the full length of the door is

acceptable.

Advertising
This manual is related to the following products: