INSTALLATION REQUIREMENTS

Exhaust system requirements

Use only 4 inch (102 mm) diameter (minimum) rigid

or fl exible metal duct and approved vent hood which

has a swing-out damper(s) that open when the dryer

is in operation. When the dryer stops, the dampers

automatically close to prevent drafts and the entrance

of insects and rodents. To avoid restricting the outlet,

maintain a minimum of 12 inches (30.5 cm) clearance

between the vent hood and the ground or any other

obstruction.

If your present system is made up of plastic duct or

metal foil duct, replace it with a rigid or semi-rigid metal

duct. Also, ensure the present duct is free of any lint prior

to installing dryer duct.

The following are specifi c requirements for proper

and safe operation of your dryer.

WARNING

FIRE HAZARD

Failure to follow these instructions can create excessive

drying times and fi re hazards.

WARNING

FIRE HAZARD

Do not install a clothes dryer with fl exible plastic or

metal foil venting materials. Flexible venting materials

are known to collapse, be easily crushed and trap lint.

These conditions will obstruct clothes dryer airfl ow and

increase the risk of fi re.

Correct

Incorrect

Correct

Incorrect