CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20

112

Parameter ID

8

Parameter

Name

Total Inertia

Data

Total inertia (Unit: 0.01 gf・cm

2

)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This parameter is used to set the inertia due to the motor rotation shaft and the mirror.

Note: Be careful about the unit. Set a value of gf・cm

2

multiplied by 100.

Related
Command
/Parameter

LQ control related parameters:
LQ Control Gain (Parameter ID = 6)
Torque Constant (Parameter ID = 8)

Parameter ID

9

Parameter

Name

Motor Current Limit

Data

Motor Current limit (Unit: %)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This parameter is used to set the upper limit of a current command value. (Setting for
each axis as a ratio to 10A)
E.g.: 90% (10A × 0.9 = 9A)
If the current remains over the upper limit for a specified time, a current saturation error
occurs.

Related
Command
/Parameter

Bit 15 “Current Saturation” becomes 1 in error read (Command ID = 15).

Parameter ID

10

Parameter

Name

Encoder Wave per Rotation

Data

Encoder periodicity (Unit: pulse)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This parameter is used to set the number of pulses per rotation of the motor encoder.
GM-1010: 1000 pulses
GM-1015: 1500 pulses
Whenever the motor model is changed, the setting of this parameter should be
changed.

Related
Command
/Parameter