Users Manual 1.20

73

A response is necessary after confirming the error

details with the control software, or RS-232C

command ID = 15 error read.

LED5

ALARM display (for Axis 2)

This LED (red) is lit when a malfunction occurs with

the controller.

A response is necessary after confirming the error

details with the control software, or RS-232C

command ID = 15 error read.

LED6

DSP2 operation (for Axis 1)

Always lights in approximately 1 sec. intervals if

DSP2 start up correctly.

LED7

DSP2 operation (for Axis 2)

Always lights in approximately 1 sec. intervals if

DSP2 start up correctly.

Note: When connecting only one axis of the motor and operating the controller (GC-201), an error will

always occur for the axis that is not connected. As a result, either LED4 or LED5 will light up, however,

as there is no problem with the operation of the connected axis, use it as is.