Parameter ID

17

Parameter

Name

#1 Digital Notch Filter Q

Data

Q value of the first digital notch filter (Unit: ×100)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This parameter is used to set the Q value of the first digital notch filter.
Set a value multiplied by 100.

Related
Command
/Parameter

#1 Notch Filter Frequency (Parameter ID = 16)
#1 Notch Filter Depth (Parameter ID = 18)

Parameter ID

18

Parameter

Name

#1 Digital Notch Filter Depth

Data

Depth of the first digital notch filter (Unit: dB)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This parameter is used to set the depth of the first digital notch filter.

Related
Command
/Parameter

#1 Notch Filter Frequency (Parameter ID = 16)
#1 Notch Filter Q (Parameter ID = 17)

Parameter ID

19

Parameter

Name

#2 Digital Notch Filter Frequency

Data

Central frequency of the second digital notch filter (Unit: Hz)

Return Value 0: Parameter setting successful

1: Parameter setting unsuccessful

Explanation

This parameter is used to set the central frequency of the second digital notch filter.

Related
Command
/Parameter

#2 Notch Filter Q (Parameter ID = 17)
#2 Notch Filter Depth (Parameter ID = 18)