Dell PowerEdge 700 User Manual

Page 28

Advertising
background image

Data error

drive, or hard drive.

Diskette Drive

," "

Troubleshooting a CD, DVD, or CD-RW/DVD Drive

,"

"

Troubleshooting SATA Hard Drives

," or "

Troubleshooting SCSI Hard

Drives

" in "

Troubleshooting Your System

."

 

Decreasing available memory

 

Faulty or improperly installed memory modules.

 

See "

Troubleshooting System Memory

" in "

Troubleshooting Your

System

."

 

Diskette drive n seek

failure

 

Incorrect configuration settings in the System

Setup program.

 

Run the System Setup program to correct the settings (see "Using the

System Setup Program" in your User's Guide).

 

Faulty or improperly installed diskette drive.

 

See "

Troubleshooting a Diskette Drive

" in "

Troubleshooting Your

System

."

 

Diskette read failure

 

Faulty or improperly inserted diskette.

 

Replace the diskette.

 

Diskette subsystem reset

failed

 

Faulty or improperly installed diskette drive.

 

See "

Troubleshooting a Diskette Drive

" in "

Troubleshooting Your

System

."

 

Diskette write protected

 

Diskette write-protect feature activated.

 

Move the write-protect tab on the diskette to the disabled position.

 

Drive not ready

 

Diskette missing or improperly inserted in diskette

drive.

 

Reinsert or replace the diskette.

 

Embedded server management

error

 

Faulty or improperly installed remote access

controller (RAC) or loose cable connection.

 

Ensure that the RAC's cable is properly connected. Ensure that the

RAC is properly installed. See "

Expansion Cards

" in "

Installing System

Options

." If the problem persists, see "

Getting Help

."

 

Error: More than one RAC

detected, system halted.

 

Two RACs are installed, or faulty or improperly

installed RAC.

 

Ensure that there is only one RAC installed and that it is installed in

the correct slot. Ensure that the RAC is properly installed. See
"

Expansion Cards

" in "

Installing System Options

." If the problem

persists, see "

Getting Help

."

 

Error: RAC cannot be used

with an add-in video card in

this slot.

 

Add-in video card is installed.

 

Ensure that the RAC is installed in the correct slot. See "

Expansion

Cards

" in "

Installing System Options

."

 

Error: RAC is not in the

correct PCI slot, system

halted.

 

The RAC card is not installed in the proper PCI

slot.

 

Ensure that the RAC is installed in the correct PCI slot. See

"

Troubleshooting Expansion Cards

" in "

Troubleshooting Your System

."

 

Error: Remote Access Card

initialization failure.

 

Faulty or improperly installed RAC.

 

Ensure that the RAC is properly installed. See "

Troubleshooting

Expansion Cards

" in "

Troubleshooting Your System

."

 

Gate A20 failure

 

Faulty keyboard controller; faulty system board.

 

See "

Getting Help

."

 

General failure

 

Operating system corrupted or improperly

installed.

 

Reinstall the operating system.

 

Hard disk controller failure

 

Incorrect configuration settings in System Setup

program; improperly installed hard drive; loose
interface or power cable; faulty hard-drive
controller subsystem.

 

Run the System Setup program to correct the drive type setting (see

"Using the System Setup Program" in your User's Guide). If the problem
persists, see "

Troubleshooting SCSI Hard Drives

" or "

Troubleshooting

SATA Hard Drives

" in "

Troubleshooting Your System

."

 

Invalid memory configuration

detected. Potential

corruption exists!

 

Memory module installation guidelines have not

been properly followed.

 

See "

Memory Module Installation Guidelines

" in "

Installing System

Options

."

 

Keyboard controller failure

 

Faulty keyboard controller; faulty system board.

 

See "

Getting Help

."

 

Keyboard data line failure

 

Loose or improperly connected keyboard cable;

faulty keyboard; faulty keyboard controller.

 

See "

Troubleshooting the Keyboard

" in "

Troubleshooting Your

System

."

 

Keyboard failure

 

Keyboard stuck key failure

 

Memory address line failure

at address, read value

expecting value

 

Faulty or improperly installed memory modules.

 

See "

Troubleshooting System Memory

" in "

Troubleshooting Your

System

."

Advertising