Memory double word logic

failure at address, read

value expecting value

 

Memory odd/even logic

failure at start address to

end address

 

Memory write/read failure at

address, read value

expecting value

 

Memory allocation error

 

Faulty application program.

 

Restart the application program.

 

Memory bank population

error!

 

Memory module installation guidelines have not

been properly followed.

 

See "

Memory Module Installation Guidelines

" in "

Installing System

Options

."

 

Memory parity interrupt at

address

 

Faulty or improperly installed memory modules.

 

See "

Troubleshooting System Memory

" in "

Troubleshooting Your

System

."

 

Memory tests terminated by

keystroke

 

The spacebar was pressed during POST to

terminate the memory test.

 

Information only.

 

No boot device available

 

Faulty or missing CD/diskette-drive subsystem,

hard drive, or hard-drive subsystem.

 

Use a bootable diskette, CD, or hard drive. If the problem persists, see

"

Troubleshooting a Diskette Drive

," "

Troubleshooting a CD, DVD, or CD-

RW/DVD Drive

," "

Troubleshooting SATA Hard Drives

," or

"

Troubleshooting SCSI Hard Drives

" in "

Troubleshooting Your System

."

 

No boot sector on hard- disk

drive

 

No operating system on hard drive.

 

Check the hard-drive configuration settings in the System Setup

program (see "Using the System Setup Program" in your User's Guide).

 

No timer tick interrupt

 

Faulty system board.

 

See "

Getting Help

."

 

Non-system disk or disk

error

 

Faulty diskette, CD/diskette-drive subsystem, or

hard-drive subsystem.

 

See "

Troubleshooting a Diskette Drive

," "

Troubleshooting a CD, DVD,

or CD-RW/DVD Drive

," "

Troubleshooting SATA Hard Drives

," or

"

Troubleshooting SCSI Hard Drives

" in "

Troubleshooting Your System

."

If the problem persists, see "

Getting Help

."

 

Not a boot diskette

 

No operating system on diskette.

 

Use a bootable diskette.

 

PCI BIOS failed to install

 

Loose cable(s) to expansion card(s); faulty or

improperly installed expansion card.

 

Ensure that all appropriate cable(s) are securely connected to the

expansion card(s). If the problem persists, see "

Troubleshooting

Expansion Cards

" in "

Troubleshooting Your System

."

 

Plug & Play Configuration

error

 

Error encountered while initializing PCI devices.

 

Install the NVRAM_CLR jumper and reboot the system (see

Figure A

-2

for jumper location). If the problem persists, see "

Troubleshooting

Expansion Cards

" in "

Troubleshooting Your System

."

 

Primary drive n

configuration error

 

Primary drive n failure

 

Faulty or improperly installed hard drive.

 Ensure that the CD drive cables are properly connected. See 
"

Troubleshooting a CD, DVD, or CD-RW/DVD Drive

" in "

Troubleshooting

Your System

."

 

Primary drive n not found

 

The specified drive on the primary channel of the

integrated hard drive controller is set to Auto in
the System Setup program, but no drive is
attached; improperly installed hard drive; loose
interface or power cable.

 

Run the System Setup program to correct the drive settings (see

"Using the System Setup Program" in your User's Guide). If the problem
persists, see "

Troubleshooting SATA Hard Drives

" or "

Troubleshooting

SCSI Hard Drives

" in "

Troubleshooting Your System

."

 

Read fault

 

Faulty diskette, CD/diskette-drive subsystem, or

hard-drive subsystem.

 

See "

Troubleshooting a Diskette Drive

," "

Troubleshooting a CD, DVD,

or CD-RW/DVD Drive

," "

Troubleshooting SATA Hard Drives

," or

"

Troubleshooting SCSI Hard Drives

" in "

Troubleshooting Your System

."

If the problem persists, see "

Getting Help

."

 

Requested sector not found

 

Reset failed

 

Improperly connected diskette drive, tape drive,

hard drive, or power cable.

 

Ensure that all cables are securely connected. If the problem persists,

see "

Getting Help

."