Error messages – Dell Latitude C540 User Manual

Page 57

Advertising
background image

AC Adapter
Rating

Computer
Undocked

Using Dell C/Port

APR

Using Dell C/Dock Expansion

Station

90 W

maximum
performance

maximum performance maximum performance

70 W

maximum
performance

maximum performance battery optimized (reduced

performance)

50 W

N/A

N/A

N/A

Error Messages

If the message is not listed, see the documentation for the operating system or the program that was
running at the time the message appeared.

Auxiliary device failure -

The touch pad, track stick, or external PS/2 mouse may be

faulty. For an external mouse, check the cable connection. Enable the Pointing Device
option in the system setup program. If the problem persists,

contact Dell

.

Bad command or file name -

Ensure that you have spelled the command correctly,

put spaces in the proper place, and used the correct pathname.

Cache disabled due to failure -

The primary cache internal to the microprocessor has

failed.

Contact Dell

.

CD drive controller failure -

The CD drive does not respond to commands from the

computer. See "

Drive Problems

."

Data error -

The floppy or hard drive cannot read the data. See "

Drive Problems

."

Decreasing available memory -

One or more memory modules may be faulty or

improperly seated. Reseat the memory modules and, if necessary, replace them. See
"

Adding Memory

.

Disk C: failed initialization -

The hard drive failed initialization. Run the Hard-Disk

Drive tests as described in "

Using the Dell Diagnostics

."

Floppy drive 0 seek failure -

The system configuration information may not match the

hardware configuration. Run the Diskette tests as described in "

Using the Dell

Diagnostics

."

Diskette read failure -

The floppy disk may be defective. If the drive access light

turns on, try a different disk. See "

Drive Problems

."

Advertising