Sensors Threshold | 37

3

Sensors Threshold

Table 3-1. Sensors Threshold

Sensor

Number

Sensor

Name

The Converting Formula

Upper non-

recoverable

Upper

critical

Upper

non-

critical

Lower non-

recoverable

Lower

critical

Lower

non-

critical

Fan

01h

FCB

FAN1

Actual_Reading (RPM) = Raw_Data x 100
0xFF

0xFF

0xFF

0x00

0x0F

0x00

02h

FCB

FAN2

Actual_Reading (RPM) = Raw_Data x 100
0xFF

0xFF

0xFF

0x00

0x0F

0x00

03h

FCB

FAN3

Actual_Reading (RPM) = Raw_Data x 100
0xFF

0xFF

0xFF

0x00

0x0F

0x00

04h

FCB

FAN4

Actual_Reading (RPM) = Raw_Data x 100
0xFF

0xFF

0xFF

0x00

0x0F

0x00

Voltage

14h

PS 12V

Actual_Reading (Volts) = Raw_Data x 0.062
0xD8

0xD4

0xCF

0xAB

0xAF

0xB4

15h

PS 5V

Actual_Reading (Volts) = Raw_Data x 0.026
0xD7

0xD3

0xCD

0xA9

0xAE

0xB3

16h

Standby

3.3V

Actual_Reading (Volts) = Raw_Data x 0.0172
0xD6

0xD3

0xCD

0xA9

0xAD

0xB3

17h

PS 3.3V

Actual_Reading (Volts) = Raw_Data x 0.026
0xFF

0xFF

0xFF

0x00

0x00

0x00

18h

PS 1.2V Actual_Reading (Volts) = Raw_Data x 0.0087

Advertising