Vlan id – Dell PowerEdge C6145 User Manual
Page 73

Appendix | 73
Set SSH/Telnet SOL Redirect enable:
1 Reserved Extended Configuration
ipmitool raw 0x30 0x01
Response: 0x02 (Reservation ID)
2 Enable SSH/Telnet SOL redirect.
ipmitool raw 0x30 0x03 0x02 0x03 0x02 0x00 0x00 0x00 0x01 0x01
(set 1 to enable)
Response: 0x01
VLAN ID
User can use LAN configuration command parameter 14H to Set or Get VLAN
ID. More VLAN information, please refer to “IPMI SPEC v2.0 errata revision
4”.
Commands
NetFn
CMD
O/M Supported
Set LAN Configuration
Parameters
(
Note: Parameter 9 and 25 are not
supported.)
Transport
01h
M
Yes
Get LAN Configuration
Parameters
(
Note: Parameter 9 and 25 are not
supported.
)
Transport 02h
M
Yes
LAN configuration Parameter 14H:
Parameter
#
Parameter Data
802.1q VLAN ID
(12-bit)
14H
data 1
[7:0] - Least significant 8-bits of the VLAN
ID. 00h if VLAN ID not used.
data 2
[7] - VLAN ID enable.
0b = disabled, 1b = enabled. If enabled, the
BMC will only accept packets for this
channel if they have 802.1q fields and their