Appendix | 73

Set SSH/Telnet SOL Redirect enable:

1 Reserved Extended Configuration

ipmitool raw 0x30 0x01
Response: 0x02 (Reservation ID)

2 Enable SSH/Telnet SOL redirect.

ipmitool raw 0x30 0x03 0x02 0x03 0x02 0x00 0x00 0x00 0x01 0x01

(set 1 to enable)
Response: 0x01

VLAN ID

User can use LAN configuration command parameter 14H to Set or Get VLAN

ID. More VLAN information, please refer to “IPMI SPEC v2.0 errata revision

4”.

Commands

NetFn

CMD

O/M Supported

Set LAN Configuration

Parameters

(

Note: Parameter 9 and 25 are not

supported.)

Transport

01h

M

Yes

Get LAN Configuration
Parameters

(

Note: Parameter 9 and 25 are not

supported.

)

Transport 02h

M

Yes

LAN configuration Parameter 14H:

Parameter

#

Parameter Data

802.1q VLAN ID

(12-bit)

14H

data 1
[7:0] - Least significant 8-bits of the VLAN

ID. 00h if VLAN ID not used.
data 2
[7] - VLAN ID enable.
0b = disabled, 1b = enabled. If enabled, the

BMC will only accept packets for this

channel if they have 802.1q fields and their

Advertising