Dell PowerEdge C6145 User Manual
Page 57

IPMI OEM Command List | 57
GET LAN
SOURCE
OEM2 14h Request:
Response:
Byte 1 – completion code
Byte 2 – Current LAN Source
00h – Shared NIC
01h – Dedicated NIC
GET FCB FW
VERSION
oem2 16H Request:
Response:
Byte 1 – completion code
Byte 2 – FCB Fw Major number
Byte 3 – FCB Fw Minor number
SET FAN
CONTROL
oem2 61H Request:
Byte 1 – Fan Control Setting
[7] – Enabled/Disabled FAN Control
0: Disabled(Default)
1: Enabled
[6:0] – Duty Cycle Setting. The rage is
from 0 to 100, others are reserved.
Response:
Byte 1 – completion code
GET FAN
CONTROL
oem2 62H Request:
Response:
Byte 1 – completion code
Byte 2 – Fan Control Setting
[7] – Enabled/Disabled FAN Control
0: Disabled(Default)
1: Enabled
[6:0] – Duty Cycle Setting. The rage is
from 0 to 100, others are reserved.