Troubleshooting the system battery, See "troubleshooting the, System battery" on – Dell PowerEdge R900 User Manual

Page 136: And "troubleshooting the

Advertising
background image

136

Troubleshooting Your System

5 Run the system board tests in the system diagnostics. See "Executing

System Diagnostics" on page 150.
If the tests fail, see "Getting Help" on page 165.

Troubleshooting the System Battery

Problem

• System message indicates a problem with the battery.
• System Setup program loses system configuration information.
• System date and time do not remain current.

NOTE:

If the system is turned off for long periods of time (for weeks or months), the

NVRAM may lose its system configuration information. This situation is caused by a

defective battery.

Action

1 Re-enter the time and date through the System Setup program. See "Using

the System Setup Program" on page 41.

2 Remove power from the system and disconnect it from the electrical outlet

for at least one hour.

3 Reconnect the system to the electrical outlet and turn on the system.
4 Enter the System Setup program.

If the date and time are not correct in the System Setup program, replace

the battery with a CR2032 battery only. See "System Battery" on page 108.
If the problem is not resolved by replacing the battery, see "Getting Help"

on page 165.

NOTE:

Some software may cause the system time to speed up or slow down. If the

system seems to operate normally except for the time kept in the System Setup

program, the problem may be caused by software rather than by a defective

battery.