Troubleshooting expansion cards, Troubleshooting, Expansion cards" on – Dell PowerEdge R900 User Manual

Page 145

Advertising
background image

Troubleshooting Your System

145

7 Ensure that the controller card is firmly seated in its connector. See "SAS

Controller Card" on page 78.

8 If you have a SAS RAID controller card, ensure that the following RAID

components are properly installed and connected:
• Memory module
• Battery

9 Verify that the cable connections between the SAS backplane(s) and the

SAS controller card are correct. See "Installing an SAS Controller Card" on

page 80.

10 Ensure that the cables are firmly connected to the SAS controller card and

the SAS backplane.

11 Close the system. See "Installing the Top Cover" on page 60.
12 Reconnect the system to its electrical outlet, and turn on the system and

attached peripherals. If the problem persists, proceed as follows:
• If you have a SAS controller card, see "Getting Help" on page 165.
• If you have a SAS RAID controller card, replace the SAS RAID card

battery. See "Installing a RAID Battery" on page 84. If replacing the

battery does not solve the problem, see "Getting Help" on page 165.

Troubleshooting Expansion Cards

NOTE:

When troubleshooting an expansion card, see the documentation for your

operating system and the expansion card.

Problem

• Error message indicates a problem with an expansion card.
• Expansion card performs incorrectly or not at all.

Action

CAUTION:

Only trained service technicians are authorized to remove the system

cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.

Advertising