Troubleshooting system memory, E "troubleshooting, System memory" on – Dell PowerEdge R900 User Manual

Page 139: See "troubleshooting, Troubleshooting system

Advertising
background image

Troubleshooting Your System

139

3 Locate the faulty fan indicated by the LCD display or diagnostic software.

For the identification number of each fan, see Figure 3-1.

4 Ensure that the faulty fan's power cable is firmly attached to the fan power

connector. See "System Fans" on page 70.

NOTE:

Wait 30 seconds for the system to recognize the fan and determine

whether it is working properly.

5 If the problem is not resolved, install a new fan. See "System Fans" on

page 70.
If the replacement fan is working properly, close the system. See "Installing

the Top Cover" on page 60.
If the replacement fan does not operate, see "Getting Help" on page 165.

Troubleshooting System Memory

Problem

• Faulty memory module.
• Faulty system board.
• Front panel status LCD indicates a problem with system memory.

Action

CAUTION:

Only trained service technicians are authorized to remove the system

cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.

1 Run the appropriate online diagnostic test. See "Using PowerEdge

Diagnostics" on page 149.

2 Turn on the system and attached peripherals.

If an error message does not appear, continue to the next step.
If an error messages appears, go to step 14.

3 Enter the System Setup program and check the system memory setting.

See "Entering the System Setup Program" on page 41.