Dell PowerVault MD3220 User Manual

Page 205

Advertising
background image

Management: Installing Array Components

205

2 From the Modular Disk Storage Manager (MDSM) software, prepare the

drive for removal. Wait until the hard-drive indicators on the drive

carrier signal that the drive can be removed safely. For more information,

see your controller documentation for information about hot-swap drive

removal.
If the drive is online, the green activity/fault indicator flashes as the drive

is powered down. When the drive indicators are off, the drive is ready for

removal.

3 Press the release button to open the drive carrier release handle. See

Figure 15-4.

4 Slide the hard drive out until it is free of the drive bay.

CAUTION:

To maintain proper system cooling, all empty hard-drive bays must

have drive blanks installed.

5 Insert a drive blank in the empty drive bay. See "Installing a Hard-Drive

Blank" on page 204.

6 If applicable, replace the front bezel. See "Installing the Front Bezel" on

page 202.

Figure 15-4. Removing and Installing a Hard Drive

1

release button

2

hard-drive carrier handle

1

2

book.book Page 205 Tuesday, June 18, 2013 2:53 PM

Advertising
This manual is related to the following products: