Rack Installation Guide

www

.dell.com | support.dell.com

3

Push the tab on the front end of the cable-management arm into a mating latch on the inner
segment of the slide assembly (see Figure 8).
The latch clicks when locked.

Figure 8.

Installing the Cable-Management Arm

4

Install a stop block on the latch on the end of the opposite slide assembly (see Figure 8).
The stop block prevents the cable-management arm from moving backward and supports the
weight of the arm with its load of installed cables.

The rack kit has two stop blocks: one for right-side mounting and one for left-side mounting.
You can only install the proper stop block.

5

Install the status-indicator cable plug into its connector.

6

Open the wire covers on the cable-management arm by lifting the center of the wire over the
top of the embossed round button on the front of the forward part of the arm, and lifting the
wire over the top of a similar round button on the back part of the arm.
The wire cover swings open to enable cables to be routed within the arm.

latch on inner segment
of slide assembly

stop block

cable-management arm

latch on end of slide assembly

tab on front end

tab on back end