0

0

MarginalPorts

0.00%[0]

0.00%[0]

FaultyPorts

0.00%[0]

0.00%[0]

MissingSFPs

0.00%[0]

0.00%[0]

ErrorPorts

0.00%[0]

0.00%[0]

Number of ports: 4

Setting the switch status policy threshold values

Use the following procedure to set the switch status policy threshold values:

1. Connect to the switch and log in using an account with admin permissions.

2. Enter the switchStatusPolicySet command.

The current switch status policy parameter values are displayed. You are prompted to enter
values for each DOWN and MARGINAL threshold parameter.

NOTE

By setting the DOWN and MARGINAL values for a parameter to 0,0 that parameter is no longer
used in setting the overall status for the switch.

3. Verify the threshold settings you have configured for each parameter.

Enter the switchStatusPolicyShow command to view your current switch status policy
configuration.

Example output from a switch

The following example displays what is typically seen from a Brocade switch, but the quantity and
types vary by platform.

switch:admin> switchstatuspolicyshow

To change the overall switch status policy parameters

The current overall switch status policy parameters:

Down

Marginal

-----------------------------------

PowerSupplies

2

1

Temperatures

2

1

Fans

2

1

Flash

0

1

MarginalPorts

25.00%[12]

10.00%[5]

FaultyPorts

25.00%[12]

10.00%[5]

MissingSFPs

0.00%[0]

0.00%[0]

ErrorPorts

0.00%[0]

0.00%[0]

Number of ports: 48

Note that the value, 0, for a parameter, means that it is
NOT used in the calculation.
** In addition, if the range of settable values in the prompt is (0..0),
** the policy parameter is NOT applicable to the switch.
** Simply hit the Return key.

The minimum number of

Bad PowerSupplies contributing to DOWN status: (0..2) [2]
Bad PowerSupplies contributing to MARGINAL status: (0..2) [1]
Bad Temperatures contributing to DOWN status: (0..4) [2]1
Bad Temperatures contributing to MARGINAL status: (0..4) [1]2