Dell POWEREDGE M1000E User Manual

Page 414

Advertising
background image

414

Fabric OS Administrator’s Guide

53-1002745-02

Working with EX_Ports

14

QOS Port

AE

Port Auto Disable:

OFF

Rate Limit

OFF

EX Port

ON

Mirror Port

OFF

Credit Recovery

ON

F_Port Buffers

OFF

Fault Delay:

0(R_A_TOV)

NPIV PP Limit:

255

CSCTL mode:

OFF

D-Port mode:

OFF

Compression:

OFF

Encryption:

ON

FEC:

ON

myswitch:admin>

Example Enabling compression on port 1 of ‘myswitch’

The subsequent portCfgShow command shows both encryption and compression to be enabled on
the port.

myswitch:admin> portdisable 1
myswitch:admin> portcfgcompress --enable 1
myswitch:admin> portenable 1
myswitch:admin> portcfgshow 1
Area Number:

1

Octet Speed Combo:

1(16G|8G|4G|2G)

Speed Level:

AUTO(SW)

AL_PA Offset 13:

OFF

Trunk Port

OFF

Long Distance

OFF

VC Link Init

OFF

Locked L_Port

OFF

Locked G_Port

OFF

Disabled E_Port

OFF

Locked E_Port

OFF

ISL R_RDY Mode

OFF

RSCN Suppressed

OFF

Persistent Disable

OFF

LOS TOV enable

OFF

NPIV capability

ON

QOS Port

AE

Port Auto Disable:

OFF

Rate Limit

OFF

EX Port

ON

Mirror Port

OFF

Credit Recovery

ON

F_Port Buffers

OFF

Fault Delay:

0(R_A_TOV)

NPIV PP Limit:

255

CSCTL mode:

OFF

D-Port mode:

OFF

Compression:

ON

Encryption:

ON

FEC:

ON

myswitch:admin>

Example Setting the secret key for the front phantom wwn projected by the FCR on the ‘edge’ switch

Use portCfgExPort EX_Port# on the remote FCR to learn the front phantom switch wwn value.

Advertising