Clearing frame monitor counters – Dell POWEREDGE M1000E User Manual

Page 509

Advertising
background image

Fabric OS Administrator’s Guide

509

53-1002745-02

Frame monitoring

20

Example

The following example displays the existing frame types and associated bit patterns on the switch.

switch:admin> fmmonitor --show
FRAME_TYPE

BIT

PATTERN

----------------------------------------
scsi

12,0xFF,0x08;

scsiread

12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x08,0x28;

scsiwrite

12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x08,0x28,0x0A,0x2A;

scsirw

12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x08,0x28,0x0A,0x2A;

scsi2reserve

12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x16,0x56;

scsi3reserve

12,0xFF,0x08;4,0xFF,0x06;40,0xFF,0x5F;41,0xFF,0x01

ip

12,0xFF,0x05;

abts

4,0xFF,0x81;40,0xFF,0x81;12,0xFF,0x0;17,0xFF,0x0;

baacc

4,0xff,0x84;12,0xff,0x00;17,0xff,00;

The following example displays configuration details for the predefined SCSI frame monitor. Notice
that in the last entry, the “-” in the Count column indicates that the monitor is configured, but is not
installed on the port.

switch:admin> fmmonitor --show SCSI

Port|Frame Type |Count

|HIGH Thres|Actions

|TIMEBASE

|CFG

-----------------------------------------------------------------------------
000001|scsi

|0x0000000000000123|1000

|Email

|None

|saved

000002|scsi

|0x0000000000000125|1000

|Email

|None

|saved

000003|scsi

|0x0000000000000143|1000

|Email

|None

|saved

000022|scsi

|-

|0

|None

|None

|saved

The following example displays values for the predefined SCSI frame monitor on port 5, every 5
seconds.

switch:admin> fmmonitor --show scsi -port 5 -timeinterval 5

Port|Count

|

----------------------
2011-03-21 00:59:50

000005|

48.3k

2011-03-21 00:59:55

000005|

48.6k

(output truncated)

Clearing frame monitor counters

1. Connect to the switch and log in using an account with admin permissions.

2. Enter the fmMonitor

--

clear command to clear the counters on the ports on which the

specified frame type is monitored.

Example

The following example clears the counters for the ABTS monitor from ports 7 through 10.

switch:admin> fmmonitor --clear ABTS -port 7-10