background image

Fabric OS Administrator’s Guide

301

53-1002745-02

Creating a logical fabric using XISLs

10

4. Configure the logical switches in each chassis:

a. Connect to the physical chassis and log in using an account with the chassis-role

permission.

b. Create a logical switch and assign it a fabric ID for the logical fabric. This FID must be

different from the FID in the base fabric. See

“Creating a logical switch or base switch”

on

page 292 for instructions.

For the example shown in

Figure 28

, you would create a logical switch with FID 1 and a

logical switch with FID 15.

c. Assign ports to the logical switch, as described in

“Adding and moving ports on a logical

switch”

on page 295.

d. Physically connect devices and ISLs to these ports on the logical switch.

e. (Optional) Configure the logical switch to use XISLs, if it is not already XISL-capable. See

“Configuring a logical switch to use XISLs”

on page 299 for instructions.

By default, newly created logical switches are configured to allow XISL use.

f.

Repeat

step a

through

step e

in all chassis that are to participate in the logical fabric,

using the same fabric ID whenever two switches need to be part of a single logical fabric.

5. Enable all logical switches by entering the switchEnable command on each logical switch that

you created in

step 4

(the base switches are already enabled).

The logical fabric is formed.

The fabricShow command displays all logical switches configured with the same fabric ID as the
local switch and all non-Virtual Fabrics switches connected through ISLs to these logical switches.

The switchShow command displays logical ports as E_Ports, with -1 for the slot and the user port
number for the slot port.