24

ATTENTION

In a multi-switch backbone fabric, modification of the FID within the backbone fabric will cause
disruption to local traffic.

Assigning backbone fabric IDs

1. Log in to the switch or Backbone.

2. Enter the switchDisable command if EX_Ports are online.

3. Enter the fosConfig

--

disable fcr command to disable the FC-FC routing service.

The default state for the FCR is disabled.

4. Enter the fcrConfigure command. At the prompt, enter the fabric ID, or press Enter to keep the

current fabric ID, which is displayed in brackets.

5. Verify the backbone fabric ID is different from that set for edge fabrics.

Multiple FC routers attached to the same backbone fabric must have the same backbone
fabric ID.

6. Enter the fosConfig

--

enable fcr command.

7. Enter the switchEnable command.

Example

switch:admin> switchdisable
switch:admin> fosconfig --disable fcr
FC Router service is disabled

switch:admin> fcrconfigure
FC Router parameter set. <cr> to skip a parameter
Please make sure new Backbone Fabric ID does not conflict with any configured
EX-Port's Fabric ID
Backbone fabric ID: (1-128)[128]

switch:admin> fosconfig --enable fcr
FC Router service is enabled

switch:admin> switchenable

FCIP tunnel configuration

The optional Fibre Channel over IP (FCIP) Tunneling Service enables you to use “tunnels” to
connect instances of Fibre Channel SANs over IP-based networks to transport all Fibre Channel ISL
and IFL traffic. FCIP is a prerequisite for configuring VEX_Ports; if you are only using FC_Ports, then
there is no need to configure FCIP tunnels.

If using FCIP in your FC-FC routing configuration, you must first configure FCIP tunnels. Once a
tunnel is created, it defaults to a disabled state. Then configure the VE_Port or VEX_Port. After the
appropriate ports are configured, enable the tunnel.

NOTE

FCIP tunnel configuration is applicable only to Fabric OS fabrics and does not apply to Brocade