Warning Messages

A warning message alerts you to a possible problem and prompts you to respond before the system continues a task. For example, before you format a
diskette, a message will warn you that you may lose all data on the diskette. Warning messages usually interrupt the task and require you to respond by
typing y (yes) or n (no).

 

Diagnostics Messages

When you run system diagnostics, an error message may result. Diagnostic error messages are not covered in this section. Record the message on a copy of
the Diagnostics Checklist in "

Getting Help

," and then follow the instructions in that section for obtaining technical assistance.

 

Alert Messages

Systems management software generates alert messages for your system. Alert messages include information, status, warning, and failure messages for
drive, temperature, fan, and power conditions. For more information, see the systems management software documentation.

Back to Contents Page

 

2-4-4

3-1-1

Slave DMA-register failure

Faulty system board. See "

Getting Help

."

3-1-2

Master DMA-register failure

3-1-3

Master interrupt-mask register failure

3-1-4

Slave interrupt-mask register failure

3-2-2

Interrupt vector loading failure

3-2-4

Keyboard-controller test failure

3-3-1

CMOS failure

3-3-2

System configuration check failure

3-3-3

Keyboard controller not detected

3-3-4

Video memory test failure

3-4-1

Screen initialization failure

3-4-2

Screen-retrace test failure

3-4-3

Video ROM search failure

4-2-1

No timer tick

4-2-2

Shutdown test failure

4-2-3

Gate A20 failure

4-2-4

Unexpected interrupt in protected mode

See "

Troubleshooting Expansion Cards

" in "Troubleshooting Your System."

4-3-1

Improperly installed or faulty memory
modules

See "

Troubleshooting System Memory

" in "Troubleshooting Your System."

4-3-2

No memory modules installed in the first
memory module connector

Install a memory module in the first memory module connector. See "

Installing a Memory Module

"

and "

Memory Module Installation Guidelines

" in "Installing System Options."

4-3-3

Faulty system board

Faulty system board. See "

Getting Help

."

4-3-4

Time-of-day clock stopped

See "

Troubleshooting the System Battery

" in "Troubleshooting Your System." If the problem

persists, see "

Getting Help

."

4-4-1

Super I/O chip failure; faulty system board Faulty system board. See "

Getting Help

."

4-4-4

Cache test failure; faulty processor

See "

Troubleshooting the Microprocessor

" in "Troubleshooting Your System."

NOTE:

Warning messages are generated by either the application or the operating system. For more information, see the documentation that

accompanied the operating system or application.