Troubleshooting a wet system, Troubleshooting a damaged system – Dell PowerEdge SC 430 User Manual

Page 26

Advertising
background image

Removing and Replacing the Front Drive Bezel Insert

 

1.

To remove the front drive bezel insert, press the two insert tabs on the front drive bezel inward and lift out the insert.

 

2.

To replace the front drive bezel insert, reverse the step above and snap the insert into place.

 

Figure 4-4. Removing and Replacing the Front Drive Bezel Insert

 

Troubleshooting a Wet System

 

Problem

l

 

Liquid spilled on the system.

l

 

Excessive humidity.

 

Action

 

 

1.

Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

 

2.

Open the system. See "

Opening the System

."


 

3.

Remove all expansion cards installed in the system. See "

Removing an Expansion Card

" in "Installing System Options."


 

4.

Let the system dry thoroughly for at least 24 hours.

 

5.

Close the system. See "

Closing the System

."


 

6.

Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the system does not start properly, see "

Getting Help

."

 

7.

If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed. See "

Installing an Expansion Card

" in

"Installing System Options."

 

8.

Run the appropriate online diagnostic test. See "

Using Server Administrator Diagnostics

" in "Running the System Diagnostics."

If the tests fail, see "

Getting Help

."

 

Troubleshooting a Damaged System

 

Problem

l

 

System was dropped or damaged.

CAUTION:

Only trained service technicians are authorized to remove the system cover and access any of the components inside the system.

Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the
computer and protecting against electrostatic discharge.