Dell PowerVault DR2000v User Manual

Page 12

Advertising
background image

ID

Issue

Description

Workaround/Solution

database did not get
backed up and tech
support had to correct
the database.

21765

System with in-sync
replication would show
pending bytes.

Corrected in version 3.1.1.

21690

During seeding, a
network interruption
caused failure of
seeding. When deleting
a container and
attempting to reboot the
system, the system
entered Maintenance
Mode.

Corrected in version 3.1.1.

21667, 21079, 21000

Slow performance
occurred on noisy
networks.

Additional TCP options were enabled in the
3.1.1 release for more effective TCP error
recovery.

21601

A Perc issue occurred
if the drive greater than
2TB sent a
UnitAttention check
condition to the Perc in
descriptor format. This
could cause the drive to
be taken offline.

Corrected in version 3.1.1 with new Perc
firmware (21.3.0-0009).

21538

Packet retransmissions
may occur with
replication packets.

Customers should turn off Deep Packet
Inspection on replication packets (especially
port 9916), including GAV(gateway antivirus),
IPS (Intrusion Prevention Service), Anti-
Spyware, etc.
To deal with TCP retransmission issues, the

following is a check list for troubleshooting

packet retransmission on the Sonicwall side:

1.

Check MTU settings. The MTU settings

are located as follows:

Firmware 6.x: Click Advanced >

Ethernet tab. Scroll to the bottom of

the page and enter the desired MTU

size.

SonicOS Standard: Click Network ->

Settings -> Ethernet Tab.

SonicOS Enhanced: Click Network -

> Interfaces. Click the Configure

12