Dell PowerVault DR2000v User Manual

Page 13

Advertising
background image

ID

Issue

Description

Workaround/Solution

icon next to the WAN interface.

Click the Advanced tab.

NOTE: It is recommended to

check the 'Fragment outbound

packets larger than WAN

MTU' if the MTU is set below

the default of 1500. Use the

'Update' button to process the

changes entered. Reboot

Sonicwall to make the change

effective.

2.

Fragment Packet Handling should be

enabled.

3.

Pre-shared Key mismatch should be

checked.

4.

Check the gateway IP address and

firewall name or serial number specified

in the VPN policy on each end of the

tunnel.

5.

Disable the hardware accelerator from

the diagnostics page.

6.

Lower the encryption settings.

7.

Check the upstream device

configuration.

8.

Check for the NAT Traversal option.

9.

On the computer where GVC is installed,

make sure the NAT Traversal option is

disabled under Connection Properties --

> Peers --> Edit --> NAT - Traversal.

21468

If the IP address
changed you could not
modify a broken
replication connection
in the GUI.

Corrected in version 3.1.1.

21405

A Solaris client running
made an invalid request
to UDP which caused
the DR to go into
Maintenance Mode.

Corrected in version 3.1.1.

21382

Adding a machine to
Global View did not
work under some rare
conditions due to
invalid characters
getting persisted into
the config file.

Corrected in version 3.1.1.

21349

Replication Disconnect
Alerts could occur

Corrected in version 3.1.1.

13