ID

Issue

Description

Workaround/Solution

failure condition from
occurring, observe
the following best
practice:
Ensure that before an

external expansion

shelf enclosure is

cabled to and

powered on to a

Release 2.0 DR4000

or DR4100 system

only after the DR

Series system has

been powered down.

Power on the DR4000 or DR4100 system.

13580

User intervention is
required when booting
up a system that was
rebooted due to a shelf
going offline.

This condition can
occur when an
external expansion
shelf enclosure goes
offline, which
requires that the DR
Series system be
rebooted. During the
DR Series system
boot up, it halts in the
PowerEdge RAID
Controller (PERC)
H800 configuration
process, and prompts
you to press <F> to
import the Foreign
Disks.

To resolve this issue, press <F> to import the
Foreign Disks, and allow the boot up process
for the DR Series system to complete and
boot normally. Once the process completes
normally, the DR Series system will come up,
and enter its Operational mode.

13790

DR Series system
performance drops
when background
initialization runs on an
external expansion
shelf.

Whenever an
external expansion
shelf enclosure is
added to the DR
Series system, this
causes a one-time
only impact to the DR
Series system
performance.
The impact is a result

of the background

initialization (BGI)

process running for

an external

expansion shelf (the

system RAID disks

require such

initialization).

There is no workaround for BGI. This is a one-
time only process that occurs when an
external expansion shelf enclosure is added.
During BGI that is associated with the

addition of an external expansion shelf

enclosure, you should expect that

performance for the DR Series system will be

slower than usual.

34