Dell PowerVault DR6000 User Manual

Page 167

Advertising
background image

Alert Message

Description/Meaning or Action

Fan <

number

> is missing.

Attach or replace the designated missing cooling fan.

Abnormal network errors detected on Network Interface
Controller <

number

>.

The Network Interface Controller errors could be caused
by network congestion or by packet errors.

Check your network. If that does not resolve the

problem, then replace the NIC.

If the NIC is embedded, the DR Series system

appliance requires service.

Network Interface Controller is missing.

Remove and reinsert the NIC.

If this does not resolve the problem, replace the NIC.

Network Interface Controller <

name

> is disconnected.

Connect it to a network and/or check your network
switches or routers for any network connectivity issues.

Network Interface Controller <

name

> is disabled.

Enable the port on the designated NIC.

Network Interface Controller <

name

> driver is bad.

Upgrade the DR Series system appliance (in the Software
Upgrade page, and click Start Upgrade).

CPU <

name

> failed.

Replace the designated failed processor.

CPU <

name

> is missing.

Reinsert or replace the designated missing processor.

DIMM <

name

> failed.

Replace the designated failed DIMM (Dual In-line Memory
Module) device.

DIMM <

name

> is missing.

Reinsert or replace the designated DIMM device.

The memory capacity of the storage appliance is

below the minimum required for correct operation.

The storage appliance requires service.

Temperature probe <

name

> failed.

The storage appliance requires service.

Voltage probe <

name

> failed.

The storage appliance requires service.

Temperature probes have recorded temperatures in the
failed range.

Check the Events page in the DR Series system for

specific temperature events and the location of the

temperature probes.

Check the data center air conditioning, ventilation, and

internal system cooling fans for any problems.

Ensure there is proper air flow through the storage

appliance, and as needed, clean the cooling vents.

Voltage probes have recorded readings in the failed
range.

Check the Events page in the DR Series system for

specific voltage events and the location of the voltage

probes.

Check the power supplies. If there are no issues with

the power supplies, have a service technician check

the DR Series system appliance to see if it requires any

servicing.

Storage Controller <

number

> failed.

Replace the RAID controller in the DR Series system.

167

Advertising
This manual is related to the following products: