Dell PowerVault DR6000 User Manual

Page 176

Advertising
background image

System Event Message

Description/Meaning or Action

Replication server failed to commit blockmap for
container <

variable

>. System is entering Maintenance

mode.

The DR Series system should self-correct itself. If condition
persists, reduce number of inodes, or contact Dell Support for
assistance or intervention.

Replication container <

variable

> is paused due to files

pending in the Cleaner process.

Run the Cleaner on the replica container. If condition persists,
contact Dell Support for intervention or assistance.

System is running a lower version of RPC. This will
stall replication on all target containers.

Please upgrade RPC to correct version. If condition persists,
contact Dell Support for intervention or assistance.

NFS client successfully mounted <

variable

>.

Informational message. No user intervention is required.

Maximum NFS connection limit <

variable

> reached,

active NFS connections <

variable

>.

You have reached the threshold limit. Reduce the number of
connections.

NFS server started successfully.

Informational message. No user intervention is required.

CIFS client successfully connected to container
<

variable

>.

Informational message. No user intervention is required.

Maximum CIFS connection limit <

variable

> reached.

You have reached the threshold limit. Reduce the number of
connections.

CIFS server failed to start <

variable

>.

Reboot the DR Series system. If issue persists, contact Dell
Support for assistance or intervention.

CIFS client connected <

variable

> times to container

<

variable

>.

Reboot the DR Series system. If issue persists, contact Dell
Support for assistance or intervention.

CIFS server started successfully.

Informational message. No user intervention is required.

Online data verification (DataCheck) started.

Informational message. If issue persists, contact Dell Support
for assistance or intervention.

Online data verification (DataCheck) suspended.

Informational message. If issue persists, contact Dell Support
for assistance or intervention.

Online data verification (DataCheck) stopped.

Informational message. If issue persists, contact Dell Support
for assistance or intervention.

Online data verification (DataCheck) resumed.

Informational message. If issue persists, contact Dell Support
for assistance or intervention.

Online data verification (DataCheck) detected
<

variable

> corruption.

Informational message. If issue persists, contact Dell Support
for assistance or intervention.

Online data verification (DataCheck) detected
<

variable

> corruptions.

Informational message. If issue persists, contact Dell Support
for assistance or intervention.

Online data verification (DataCheck) failed to start.

Informational message. If issue persists, contact Dell Support
for assistance or intervention.

System Event = Type 4

Unable to load deduplication dictionary <

variable

>.

Use the DR Series system CLI maintenance --configuration --
reinit_dictionary command. If this issue persists, contact Dell
Support for assistance or intervention.

176

Advertising
This manual is related to the following products: