Alert Message

Description/Meaning or Action

Storage Controller <

number

> is missing.

Reinsert or replace the RAID controller in the DR Series
system.

Storage Controller <

number

> has an illegal configuration. The expected number of virtual drives is <

number

>, and

the actual number of virtual drives found was <

number

>.

Run the Dell Restore Manager (RM) utility to repair the

drive configuration mismatch.
The expected number of enclosures is <

number

>, and the

actual number of enclosures found was <

number

>.

Check the SAS cable connections between the storage

controller and all its enclosures.

Check the power cable connections to the enclosure

power supplies.

Physical disk <

number

> failed.

Replace the physical disk that failed.

Physical disk <

number

> is missing, removed, or it cannot

be detected.

Reinsert or replace the physical disk.

Physical disk <

number

> predictive failure reported.

Replace the physical disk.

NOTE: Even though the disk may not have failed yet,
the recommended best practice is to replace the disk.

Physical disk <

number

> is an unsupported type.

This disk type is unsupported and cannot be used in this
configuration.
Replace the unsupported physical disk with a Dell-

supported SAS physical disk.

Physical disk <

number

> has been manually set to offline

with a configuration command.

Remove the physical disk and reinsert it (the drive is non-
operational in this state).

Physical disk <

number

> is foreign.

This can occur when a storage controller has been
replaced or all drives have been migrated from another
system. In such cases, the foreign configuration should be
imported.
If this is seen on a single physical disk, the foreign

configuration should be cleared.

NOTE: This condition can also be seen when a drive
is removed and reinserted while a rebuild is still in
progress.

Virtual Disk <

number

> failed.

Replace any failed or missing physical disk(s) and run the
Dell Restore Manager (RM) utility.

Virtual Disk <

number

> has an invalid layout.

Run the Dell Restore Manager (RM) utility to repair this
installation.

<

device

> failed.

Verify that the device is present, and then check that

the cables are properly connected. For more

information, see the

Dell DR Series System Owner’s

Manual

to verify the system cabling is correct.

Check the connection to the controller battery and the

status of battery health.