System Event Message

Description/Meaning or Action

Unable to locate deduplication dictionary <

variable

>.

Use the DR Series system CLI maintenance --configuration --
reinit_dictionary command. If issue persists, contact Dell
Support for assistance or intervention.

Cleaner process run <

variable

> started.

Informational message. No user intervention is required.

Cleaner process run <

variable

> completed in

<

variable

> milliseconds (ms).

Informational message. No user intervention is required.

Cleaner process encountered input/output (I/O) errors. Maintenance-based issue with the DR Series system. Check

status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.

Failure to sync NVRAM <

variable

>.

NVRAM hardware issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands.

Failure in reading from NVRAM <

variable

>.

NVRAM hardware issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands.

Failure in writing to NVRAM <

variable

>.

NVRAM hardware issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands.

Failure to write sync NVRAM <

variable

>.

NVRAM hardware issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands.

Datastore <

variable

> length mismatch <

variable

>.

Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.

Data volume capacity threshold reached.

Informational message. No user intervention is required.

Out of space. Rollback of updates on object <

variable

>

failed. Restarting file server.

Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.

Failure reading from data volume.

Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.

Failure writing to data volume.

Maintenance-based issue with the DR Series system. Check
status using Maintenance mode or DR Series system CLI
commands. Contact Dell Support as needed.

Checksum verification on metadata failed.

Contact Dell Support for assistance or repair the filesystem.
For repairs, see

About The DR Series Maintenance Mode

.

Optimization engine log replay failed.

Contact Dell Support for assistance or repair the filesystem.
For repairs, see

About The DR Series Maintenance Mode

.

Decompression of datastore failed <

variable

>.

Contact Dell Support for assistance or intervention.

Failed to clean active datastore <

variable

>.

Contact Dell Support for assistance or intervention.