Table 9. DR Series System Event Messages

System Event Message

Description/Meaning or Action

System Event = Type 1

System memory usage has returned to an optimal
level.

Informational message. No user intervention is required.

A high level of system process usage has been
detected, if it persists, please collect system
diagnostics.

Informational message. No user intervention is required.

System process usage has returned to an optimal
level.

Informational message. No user intervention is required.

A high-temperature reading has been detected on the
NVRAM PCI controller. System will operate only in a
read-only mode. Please check system airflow.

Informational message. No user intervention is required.

A high-temperature reading has been detected on the
NVRAM PCI controller. System will not become
operational until the temperature reduces to an
ambient value of 55 degrees Celsius (131 degrees
Fahrenheit).

Informational message. No user intervention is required. If
issue persists, contact Dell Support for assistance or
intervention.

The next NVRAM capacitor health check is scheduled
for <

variable

>.

Informational message. No user intervention is required.

Windows Active Directory client is unable to contact
the Active Directory domain server.

Informational message. No user intervention is required.

Active Directory domain server connectivity is
restored.

Informational message. No user intervention is required.

The system IP address has changed from <

variable

> to

<

variable

>.

Informational message. No user intervention is required.

Filesystem scan has been requested. Switching to
Maintenance mode. Filesystem has read-only access.

Informational message. No user intervention is required.

NVRAM not detected. Ensure card is seated properly.

Verify that the NVRAM card is seated properly in the DR
Series system appliance. Contact Dell Support for assistance
or intervention.

NVRAM capacitor is disconnected.

Contact Dell Support for assistance or intervention.

NVRAM capacitor has degraded.

Contact Dell Support for assistance or intervention.

NVRAM SSD is disconnected.

Contact Dell Support for assistance or intervention.

NVRAM has failed to backup or restore data during the
last boot.

Contact Dell Support for assistance or intervention.

NVRAM hardware failure.

Contact Dell Support for assistance or intervention.

Data volume is not present. Check that all drives are
inserted and powered up.

Contact Dell Support for assistance or intervention.

Filesystem server failed to start after multiple attempts. Contact Dell Support for assistance or intervention.