Target settings, Initiator settings continued – Dell PowerVault NX3100 User Manual
Page 38

38
Configuring Secured iSCSI Connections Using CHAP
Target Settings
Configure the Target settings of CHAP as described in "iSCSI Target
Settings" on page 36 and perform the following steps:
1 In the <Target Name> Properties window, select the Authentication tab.
2 Select the check box for Enable reverse CHAP authentication. In the
User name field, enter the IQN of the Initiator.
3 In the Reverse secret field enter the Secret value that you set in the Initiator.
NOTE:
Ensure that the reverse secret is not the same as the CHAP secret.
The reverse secret must contain 12 to 16 characters.
Initiator Settings Continued
1 Configure the Initiator settings for CHAP as described in "iSCSI Initiator
2 In the Advanced Settings window→ select CHAP logon information→
enter the User name and Target secret. Select the check box for Perform
mutual authentication and click OK.
You can log in only if you have credentials that you entered for the Target
and Initiator.