Dell OptiPlex Gxi User Manual

Page 56

Advertising
background image

3-2

Dell OptiPlex GXi Systems Service Manual

Table 3-1. POST Beep Codes

Beep Code

Error

Probable Causes

1-3

Monitor not detected

Disconnected or faulty
monitor

1-1-3

NVRAM write/read failure

Defective system board

1-1-4

BIOS checksum failure

Faulty BIOS or defective
system board

1-2-1

1-2-2

1-2-3

Programmable interval-timer
failure

DMA initialization failure

DMA page register write/
read failure

Defective system board

1-3-1

Main-memory refresh verifi-
cation failure

Faulty or improperly seated
DIMM or defective system
board

1-3-2

No memory installed

No memory installed or faulty
or improperly seated DIMM

1-3-3

1-3-4

1-4-1

1-4-2

2-1-1
through
2-4-4

Chip or data line failure in the
first 64 KB of main memory

Odd/even logic failure in the
first 64 KB of main memory

Address line failure in the
first 64 KB of main memory

Parity failure in the first
64 KB of main memory

Bit failure in the first 64 KB
of main memory

Faulty or improperly seated
DIMM

3-1-1

3-1-2

3-1-3

3-1-4

Slave DMA-register failure

Master DMA-register failure

Master interrupt-mask regis-
ter failure

Slave interrupt-mask register
failure

Defective system board

3-2-4

Keyboard-controller test
failure

Faulty keyboard controller
(defective system board)

Advertising