Dell PowerEdge 1900 User Manual

Page 18

Advertising
background image

18

About Your System

E1414

CPU # Thermtrip

Specified microprocessor is out of
acceptable temperature range and
has halted operation.

See "Troubleshooting System
Cooling Problems" on page 109.
If the problem persists, ensure
that the microprocessor heat
sinks are properly installed. See
"Troubleshooting the
Microprocessors" on page 118.

NOTE:

The LCD continues to

display this message until the
system’s power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the Dell OpenManage
Baseboard Management
Controller User’s Guide

for

information about these utilities.

E1418

CPU # Presence

Specified processor is missing or
bad, and the system is in an
unsupported configuration.

See "Troubleshooting the
Microprocessors" on page 118.

E141C

CPU Mismatch

Processors are in a configuration
unsupported by Dell.

Ensure that your processors
match and conform to the type
described in the Microprocessor
Technical Specifications outlined
in your system’s Getting Started
Guide.

E141F

CPU Protocol

The system BIOS has reported a
processor protocol error.

See "Getting Help" on page 131.

E1420

CPU Bus PERR

The system BIOS has reported a
processor bus parity error.

See "Getting Help" on page 131.

E1421

CPU Init

The system BIOS has reported a
processor initialization error.

See "Getting Help" on page 131.

E1422

CPU Machine Chk

The system BIOS has reported a
machine check error.

See "Getting Help" on page 131.

E1618

PS # Predictive

Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.

See "Troubleshooting the Power
Supply" on page 108.

Table 1-4.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions