About Your System

Solving Problems Described by LCD Status Messages

When a single message appears on the status LCD, locate the code in Table 1-4 and perform the
suggested corrective action. The code on the LCD can often specify a very precise fault condition that is
easily corrected. For example, if the code

E0780

MISSING CPU 1

appears, you know that a

microprocessor is not installed in socket 1.

In contrast, you might be able to determine the problem if multiple related errors occur. For example, if
you receive a series of messages indicating multiple voltage faults, you might determine that the problem
is a failing power supply.

E2118

Fatal NB Mem CRC

One of the connections in the

Fully Buffered DIMM (

FBD)

memory subsystem link on the
Northbound side has failed.

See "Troubleshooting System
Memory" on page 110.

E2119

Fatal SB Mem CRC

One of the connections in the
FBD memory subsystem link on
the Southbound side has failed.

See "Troubleshooting System
Memory" on page 110.

I1910

Intrusion

System cover has been removed.

Information only.

I1911

>3 ERRs Chk Log

LCD overflow message.

A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.

Check the SEL for details on the
events.

I1912

SEL Full

System Event Log is full of
events, and is unable to log any
more events.

Clear the log by deleting event
entries.

W1228

ROMB Batt < 24hr

Warns predictively that the RAID
battery has less than 24 hours of
charge left.

Replace RAID battery. See
"Replacing the SAS RAID
Controller Daughter Card
Battery" on page 92.

NOTE:

For the full name of an abbreviation or acronym used in this table, see the "Glossary" on page 155.

Table 1-4.

LCD Status Messages (continued)