About Your System

E1913

CPU & Firmware

Mismatch

The BMC firmware does not
support the CPU.

Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.

E2010

No Memory

No memory is installed in the
system.

Install memory. See "Memory" on
page 80.

E2011

Mem Config Err

Memory detected, but is not
configurable. Error detected
during memory configuration.

See "Troubleshooting System
Memory" on page 110.

E2012

Unusable Memory

Memory is configured, but not
usable. Memory subsystem
failure.

See "Troubleshooting System
Memory" on page 110.

E2013

Shadow BIOS Fail

The system BIOS failed to copy
its flash image into memory.

See "Troubleshooting System
Memory" on page 110.

E2014

CMOS Fail

CMOS failure. CMOS RAM not
functioning properly.

See "Getting Help" on page 131.

E2015

DMA Controller

DMA controller failure.

See "Getting Help" on page 131.

E2016

Int Controller

Interrupt controller failure.

See "Getting Help" on page 131.

E2017

Timer Fail

Timer refresh failure.

See "Getting Help" on page 131.

E2018

Prog Timer

Programmable interval timer
error.

See "Getting Help" on page 131.

E2019

Parity Error

Parity error.

See "Getting Help" on page 131.

E201A

SIO Err

SIO failure.

See "Getting Help" on page 131.

E201B

Kybd Controller

Keyboard controller failure.

See "Getting Help" on page 131.

E201C

SMI Init

System management interrupt
(SMI) initialization failure.

See "Getting Help" on page 131.

E201D

Shutdown Test

BIOS shutdown test failure.

See "Getting Help" on page 131.

E201E

POST Mem Test

BIOS POST memory test failure. See "Troubleshooting System

Memory" on page 110. If problem
persists, see "Getting Help" on
page 131.

Table 1-4.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions